MV-90, Power Cable, 25 KV, 1/C, Cu/XLPE/CWS/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Features
UL Listed as MV-90. Rated as Sunlight Resistance. Oil Resistance I jacket. True Triple extrusion system and
closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application

Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards

UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV - 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV - 46 kV.

Specifications

Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400. On request, strand filled or compressed strand. Sizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE). On request, TR-XLPE.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Solid soft annealed uncoated copper wires per ASTM B3, helically applied and uniformly spaced.
6. Binder Tape: A suitable tape, as required.
7. Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.
  
100% Insulation Levels (260 mil)133% Insulation Levels (320 mil)
SizeNumber of StrandsConductor NominalDiameter Over InsulationJacket ThicknessApproximate Outside DiameterApproximate Net WeightDiameter Over InsulationJacket ThicknessApproximate Outside DiameterApproximate Net Weight
CopperAluminumCopperAluminum
AWG of kcmil ininmilinlb/kftinmilinlb/kft
1190.30.85801.14715535-----
1/0190.340.89801.188045771.01801.32929702
2/0190.380.93801.229136271.05801.361042756
3/0190.420.98801.2710486881.10801.411181821
4/0190.481.03801.3412387831.15801.461353898
250370.521.09801.413998611.21801.521517980
300370.571.14801.4515839391.26801.5717061061
350370.621.18801.49176710141.30801.6118931139
400370.661.22801.54194710871.34801.6620761216
500370.741.3801.61230412291.421101.7925441469
600610.811.391101.76277814871.511101.9129721682
750610.911.481101.86330516921.601102.0135091896
1000611.061.641102.04422820781.761102.1643982248